-
TW-D2121 Door Frame Metal Detector
Read moreGeneral Outer frame 2220mm(H) x820mm(W)x500mm(D) Inner frame 2000mm(H)x700mm(W)x500mm(D) Electrical current AC100V~240V 50/60Hz Power 10W Unit weight 70KG Signal Frequency 7000-8999Hz(adjustable) Work Environment -20C to +45C Sensitivity Adjustable Level 0-99 Alarm Sound and light Max Distance 0.3m at low sensitivity;0.5m at high sensitivity Configuration Master Control Board Metal-detect-door-mainbd, REV120 Digital keypad A&C door panel board, REV030 Digital Display Location Board A&C door zone board, REV030 Speaker Loudspeaker,8 2W,Black,75mmx32mmx27mm Weight 630kg Software(Optional) Operation way Remote control only Sensibility With the highest sensibility, it can detect the metal article as small as the clip. With the range of 0-100, they can be adjusted the Sensibility easily, pre-set the weight, volume, size and location in respect of the metal Articles and eliminate the fals Infrared Counting The intelligent counter can calculate the number of Passenger flows and the times of alarm Alarm Settings Twelve kinds of alarm sound Detecting Areas Allocation of Twelve mutual over-lapping detecting areas, simultaneous alarming from multi-areas and accurately ascertaining the location of the metal articles according to the layout of the metal particles Operating Environment Operation Temperature/Humidity 5 ℃-40 ℃/0%-90% (non-condensing) Storage Temperature/Humidity -20 ℃-55 ℃/0%-98% (non-condensing) Operation Power 220V AC(±10%) 50±3Hz (Optional: 100V AC, -
TW-D2181 Door Frame Metal Detector
Read moreGeneral Outer Frame 2220mm(H) x820mm(W)x500mm(D) inner Frame 2000mm(H)x700mm(W)x500mm(D) Electrical Current AC100V~240V 50/60Hz Power 10W Unit Weight 70KG Signal Frequency 7000-8999Hz(adjustable) Work Environment -20 °C to +45 °C Sensitivity Adjustable Level 0-99 Alarm Sound and light Max Distance 0.3m at low sensitivity;0.5m at high sensitivity Configuration Master Control Board Metal-detect-door-mainbd, REV120 Digital Keypad A&C door panel board, REV030 Digital Display Location Board A&C door zone board, REV030 Speaker Loudspeaker,8 2W,Black,75mmx32mmx27mm Software Operation Way Remote control only Sensibility With the highest sensibility, it can detect the metal article as small as the clip. With the sensibility range of 0-100, it can be easily adjusted, pre-set the weight, volume, size and location in respect of the metal Articles and eliminate the false alar Infrared Counting The intelligent counter can calculate the number of Passenger flows and the times of alarm Alarm Settings Eighteen kinds of alarm sound Detecting Areas Allocation of eighteen mutual over-lapping detecting areas, Simultaneous alarming from multi-areas and accurately ascertaining the location Of the metal articles according to the layout of the metal particles Operating Environment Operation temperature/Humidity 5°C 40 °C/0%-90%(non-condensing) Storage temperature/Humidity -20 °C 55 °C/0%-98%(non-condensing) Operation Power 220VAC(±10%) 50±3Hz (Optional 100VAC,110VAC,120VAC,200VAC) -
TW-D2331 Door Frame Metal Detector
Read moreGeneral Outer Frame 2220mm(H) x820mm(W)x500mm(D) Inner Frame 2000mm(H)x700mm(W)x500mm(D) Electrical Current AC100V~240V 50/60Hz Power 10W Unit Weight 90KG Signal Frequency 7000-8999Hz(adjustable) Work Environment -20C to +45C Sensitivity Adjustable Level 0-99 Alarm Sound and light Max Distance 0.3m at low sensitivity; 0.5m at high sensitivity Configuration Master Control Board Metal-detect-door-mainbd, REV120 Digital Keypad A&C door panel board, REV030 Digital Display Location Board A&C door zone board, REV030 Speaker Loudspeaker,8 2W,Black,75mmx32mmx27mm Software Operation Way Remote control only Sensibility With the highest sensibility, it can detect the metal article as small as the clip. With the sensibility range of 0-100, it can be easily adjusted, pre-set the weight, volume, size and location in respect of the metal Articles and eliminate the false alar Infrared Counting Intelligent counter can calculate the number of Passenger flows and the times of alarm. Alarm Settings 33 kinds of alarm sound Detecting Areas Allocation of thirtythree mutual over-lapping detecting areas, simultaneous alarming from multi-areas and accurately ascertaining the location of the metal articles according to the layout of the metal particles Operating Environment Operation Temperature/Humidity 5 ℃-40 ℃/0%-90% (non-condensing) Storage Temperature/Humidity -20 ℃-55 ℃/0%-98% (non-condensing) Operation Power 220V AC(±10%) 50±3Hz (Optional: 100V AC, 110V AC, 120V AC, 200V AC) -
TW-D2601 Door Frame Metal Detector
Read moreGeneral Specification Outer Frame 2220mm(H) x820mm(W)x500mm(D) inner Frame 2000mm(H)x700mm(W)x500mm(D) Electrical Current AC100V~240V 50/60Hz Power 10W Unit Weight 70KG Signal Frequency 7000-8999Hz(adjustable) Work Environment -20 °C to +45 °C Sensitivity Adjustable Level 0-299 Alarm Sound and light Max Distance 0.3m at low sensitivity;0.5m at high sensitivity Configuration Master Control Board Metal-detect-door-mainbd, REV120 Digital Keypad A&C door panel board, REV030 Digital Display Location Board A&C door zone board, REV030 Speaker Loudspeaker,8 2W,Black,75mmx32mmx27mm Software(Optional) Operation Way Remote control only Sensibility With the highest sensibility, it can detect the metal article as small as the clip. With the sensibility range of 0-99, it can be easily adjusted, pre-set the weight, volume, size and location in respect of the metal Articles and eliminate the false alarm Infrared Counting The intelligent counter can calculate the number of Passenger flows and the times of alarm. Alarm Setting Six kinds of alarm sound Detecting Areas Allocation of six mutual over-lapping detecting areas, Simultaneous alarming from multi-areas and accurately ascertaining the location Of the metal articles according to the layout of the metal particles. Operating Environment Operation temperature/Humidity 5°C 40 °C/0%-90%(non-condensing) Storage temperature/Humidity -20 °C 55 °C/0%-98%(non-condensing) Operation Power 220VAC(±10%) 50±3Hz (Optional 100VAC,110VAC,120VAC,200VAC) -
TW-D2801 Door Frame Metal Detector
Read moreTechnical Parameters Power Supply 220V/AC Power <15W External Dimension 2200mm(H)*820mm(W)*550mm(D) Passageway Dimension 2000mm(H)*700mm(W)*550mm(D) Work Environment -20°C- +45°C Main Case Packing 0.755m*0.485m*0.255m (Carton) Probe Packing 2.27m*0.62m*0.19m(Carton) Volume In Total 0.361m Weight 50kg (Approximate) Verification Mode & Capacity Standard One Main Case One Left Probe One Right Probe Standard One Power Line Eight Screws Standard One Instruction (Including one Certificate of Quality & Guarantee Repair List) -
TW100SE Door Frame Metal Detector
Read moreTechnical Parameters Power Supply 220V/AC Power <30V External Dimension 2220mmH)*800mm(W)*400m(D) Passageway Dimension 1980mm(H)*700mm(W)*300mm(D) Work Environment -20℃ to +45℃ Main Case Packing 0.75m*0.245m*0.0.305m (Carton) Probe Packing 2.26m*0.0.36m*0.18m (Carton) Volume In Total 0.25m Weight 40kg (Approximate) Verification Mode & Capacity Standard One Main One Main Case One Left Probe One Right ProbeCase One Left Probe One Right Probe Standard One Power Line Eight Screws Standard One Instruction (Including one Certificate of Quality & Guarantee Repair List)
Showing all 6 results